20 Compact T1 - Release 6.1
Quick Start
Local and Remote Management Option
Local and Remote Management Option
This Quick Start Guide will focus on CLI and DIP switches. If you need further
information on other management options, please refer to the Compact T1 User
Manual.
l Local using CLI, Telnet, SNMP or DIP Switches (Controller and voice cards)
l Remotely over an in-band DS0 or through the Access Navigator over the FDL or
an in-band DS0
Command Line Interface (CLI)
You can access the CLI using either of the following methods:
l RS-232 connected to the DB-9 port.
l Telnet via Ethernet (10Base-T)
Setting up a CLI connection
To connect to the CLI via the RS-232 port, set up a connection to a PC serial port
or dumb terminal using Hyperterm, ProComm, or similar terminal emulation
software:
l Set the port settings to: 9600 baud 8/N/1/No Flow Control
l Set the terminal emulation screen size to 24 lines by 80 characters.
l The Compact T1 default is set configure locally (using DIP switches). Use the
set local off command to enable the use of CLI commands.