Hardware Installation Guide
revision 1 — 143
30 ISC Communication
The following information can be used to configure communication for Lenel controllers unless otherwise
stated.
30.1 LAN Connections
For LAN panels, any baud rate set on an ISC (LNL-500, 1000, or 2000 primary path (port 1) via DIP
switches 6 and 7) will work as long as the baud rate on the Lantronix box is set to match (via the “change
speed” command).
The primary path of the LNL-2000 connected to a Lantronix box can have its baud rate set to the highest
(115,200) baud rate. The Lantronix box simply needs to have its serial speed at 115,200 as well. In order for
115,200 baud to work reliably on any connection (direct serial, dedicated LAN, or dial-up on a dedicated
phone line), a wire from CTS to RTS1/R1+ on the LNL-2000 Port 1 is required.
The speed of the secondary path (port 6) on the LNL-2000 is always 38400 baud. This is not configurable at
the hardware level. Also, the MSSLITE currently only supports 38400 baud with the LNL-2000, regardless
of the port.
For UL Certified installations, these communication devices, if not directly powered and mounted to the
controller, must be mounted in their own CTX enclosures for their own unique applications unless otherwise
noted. The power for the LAN connection hardware must be provided by the control power supply (LNL-
AL400ULX).
30.1.1 Lantronix Devices
The EZWebCon management utility software may be used to configure Lantronix devices and update their
firmware. Instead of entering commands at the Local prompt, configuration can be done through on-screen
menus.
EZWebCon configuration wizard
Vista de página 0
1 2 3 4 5 6 ... 34 35

Resumo do Conteúdo

Página 1 - 30 ISC Communication

Hardware Installation Guiderevision 1 — 14330 ISC CommunicationThe following information can be used to configure communication for Lenel controllers

Página 2

ISC Communications152 — revision 1

Página 3

Hardware Installation Guiderevision 1 — 15330.4.2 Security EnhancementsPast installations may have contained vulnerabilities which could lead to unaut

Página 4 - 30.2.3 Configuring the ETHLAN

ISC Communications154 — revision 1After the firmware upgrade has been completed, disable port 77FE to prevent unauthorized access to this device.Other

Página 5

Hardware Installation Guiderevision 1 — 155• LNL-ETHLAN-MICR with firmware version 5.4 If Micro-100 unit's power is cycled,the unit will not res

Página 6 - 30.3.1 ETHLAN-MICR Standoffs

ISC Communications156 — revision 12. Start HyperTerminal. The Connection Description window will open with the “New Connection” setting. (Choose New C

Página 7 - LITE to ISC

Hardware Installation Guiderevision 1 — 15710. The software will next ask you if you wish to set the gateway. Answer yes and type the gateway IP addre

Página 8

ISC Communications158 — revision 1Step 2: Entering the Serial Port Setup Menu1. Type 1 and then press the <Enter> key to enter the serial port s

Página 9

Hardware Installation Guiderevision 1 — 1593. You will now be back at the setup screen. Type 9 and then press the <Enter> key to save the setup

Página 10 - ISC Communications

ISC Communications160 — revision 1ISC to Lantronix CoBox Token Ring Serial Server ConfigurationTOKEN RING NETWORK9-pin female2 3 5

Página 11 - 30.4.3 Firmware

Hardware Installation Guiderevision 1 — 16130.6 Lantronix CoBox-DRThe ISC can alternatively be connected to the Lantronix CoBox-DR unit. Use the follo

Página 12

ISC Communications144 — revision 1The latest version of EZWebCon can be downloaded from the Lantronix website (www.lantronix.com). For detailed inform

Página 13 - 30.4.5 Removal of Reset Pin

ISC Communications162 — revision 1ACDCACGNDGNDGNDIN2IN1 A B CJ9J14232 4 852W 4WJ1TXDTR1+RXDTR1-RTSR1+CTSR1-GNDTR2+TR2-

Página 14

Hardware Installation Guiderevision 1 — 163To configure the server and channel 1, refer to the following screenshots. Information is available for hex

Página 15 - Hardware Installation Guide

ISC Communications164 — revision 1SDS1100 to ISC, 2-wire RS-485A C D CA CGN DGN DGN DI N2I N1 A B CJ9J14232 48 52W 4WJ1TX DTR 1

Página 16

Hardware Installation Guiderevision 1 — 165SDS1100 to ISC, 4-wire RS-485A C D CA CGN DGN DGN DI N2I N1 A B CJ9J14232 48 52W

Página 17

ISC Communications166 — revision 130.7.1 Configuration of the SDS1100/1101/CoBox-FLTo configure this Lantronix device, perform the following procedure

Página 18

Hardware Installation Guiderevision 1 — 167Server configurationa. IP Address. If DHCP is not used to assign IP addresses, enter the IP address manuall

Página 19 - 30.6 Lantronix CoBox-DR

ISC Communications168 — revision 1c. Flow. Flow control sets the local handshaking method for stopping serial input/output. The default setting is 00.

Página 20 - Serial RJ-45

Hardware Installation Guiderevision 1 — 169Step 1: Establish a serial connection with ETHLANWith the power OFF on the UDS device, establish a serial c

Página 21

ISC Communications170 — revision 16. You can close your current HyperTerminal session.Step 3: Configure the UDS ETHLAN Make sure that the device is po

Página 22 - 485 232

Hardware Installation Guiderevision 1 — 1719. At this point, make sure that switch 5 on the ISC is configured correctly for hardware flow control. It

Página 23 - Configuration

Hardware Installation Guiderevision 1 — 1455. At this point, press the <Enter> key. (It may take a few seconds to complete booting).• Power shou

Página 24 - Using Telnet

ISC Communications172 — revision 1Wiring for RS-232 4-wire.Ports 1 and 6 wiring configuration for 4-wire (RS-232)ISC 25-pin connectorTXD/TR1+ Pin 2RXD

Página 25

Hardware Installation Guiderevision 1 — 173A C DCA CGNDGNDGNDI N2I N1 A B CJ9J14232 48 52W 4WJ1TXDTR1+RX DTR1-RTSR1+CTSR1-GNDTR2

Página 26 - Using a Terminal Program

ISC Communications174 — revision 1Unit Setup (RS-232 4-wire)As of March 2004, the current firmware version is 4.5. Connect to the unit via Telnet thro

Página 27

Hardware Installation Guiderevision 1 — 175A C D CA CGNDGNDGNDIN2IN1 A B CJ9J1 4232 48 52W 4WJ1TXDTR1+RX DTR1-RTSR1+CTSR1-GNDTR

Página 28

ISC Communications176 — revision 1Unit Setup (RS-485 2-wire)As of March 2004, the current firmware version is 4.5. Connect to the unit via Telnet thro

Página 29

Hardware Installation Guiderevision 1 — 1779 or 25 Pin Connector5 2 3 7 3 2DB 9 Pin Male DB 25 Pin FemaleWorkstation (PC)R

Página 30 - Wiring for RS-232 4-wire

ISC Communications146 — revision 130.2.3 Configuring the ETHLANAny additional changes specific to the hardware that the Lantronix box is connecting to

Página 31

Hardware Installation Guiderevision 1 — 14712. For flow control, type:change flow control [FLOW CONTROL]and press <Enter>, where [FLOW CONTROL]

Página 32 - Wiring for RS-485 2-wire

ISC Communications148 — revision 1Note: The ARP/ping method only works during the first two minutes of LNL-ETHLAN-MICR operation. If this process is n

Página 33

Hardware Installation Guiderevision 1 — 149Richco plastic P/N LMSP-7-0130.4 CoBox Micro 100The CoBox Micro 100 device plugs directly into the LNL-2000

Página 34 - Common Flow Control Values

ISC Communications150 — revision 14. Telnet to the assigned IP address and port 1, this should fail quickly (2-3 seconds). This will force CoBox Micro

Página 35

Hardware Installation Guiderevision 1 — 151n. Send Char 2 = 00When these changes have been made, type ‘9’ at the main screen to save the changes and e

Comentários a estes Manuais