Black Box IC050C Manual de Instruções

Consulte online ou descarregue Manual de Instruções para Modems Black Box IC050C. Black Box IC050C Instruction manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - GEH-7275

March 10, 1999GEH-7275kV RSX - RS232/RS485 Communications OptionInstruction Manual

Página 2

Page 10programmable features; there are no AMRAtables in the option board. It simply providesa pass through communications link to thekV Meter. In

Página 3

Page 11Figure 1: Option board stackThe Revenue Guard option board is not partof this stack and is not affected by thepresence of other option boards

Página 4 - Table of Contents

Page 12or, it may be installed directly to the LP-2 option board. Either way, the I/O-2option board is installed in a similarmanner to the LP-2 optio

Página 5 - APPENDIX 20

Page 13kV™ Meters with 26 pin headersinstead of 30 pin headers cannot beretrofitted with the kV RSX OptionBoard .6. With the kV RSX Option Board “s

Página 6 - External Modem mode

Page 144. Check the headers on the kV RSXboard to make sure that the pins are notbent or out of position. Orient thesmallest black connector such

Página 7 - Call Origination

Page 15Figure 13 : Battery cover installationOption Board CompatibilityIntroductionThe kV™ RSX Option Board may be used inconjunction with the RG-1

Página 8 - Power Outage Calls (optional)

Page 16I/O-2 Input/Output OptionThe I/O-2 Input/Output option board (GE part# 9938226004) is a direct replacement forthe I/O-1 option board (see abov

Página 9 - RS-232 Simple Serial

Page 17Testing MeterCalibrationIf the kV RSX is in simple serial mode,meter calibration can be tested in kV RSXequipped kV™ Meters as outlined in the

Página 10 - Installing the kV RSX

Page 18connection and carrier detected. Bymonitoring this LED (as well as any LEDs onthe external modem), correct operation ofthe kV RSX, can be ver

Página 11 - Figure 3: External Modem Mode

Page 19Call-in On Outage Upgrade KitOrder GE part number 9935143001. This kitcontains the following material:Component GE Part # QtyOutage Battery 9

Página 12 - Installation on S-base Meters

Page 2Notice:The information contained in this document is subject to change without notice.GE makes no warranty of any kind with regard to this mate

Página 13 - Installation on A-base Meters

Page 20AppendixExternal Modem ModeFor correct operation in external modem mode, the kV RSX requires that the operating modejumpers be positioned corr

Página 14 - Battery Installation

Page 21Local Echo - Local echo of modem commands must be set to off (E0).On/Off Hook Control - The external modem is initialized to on hook (H0).Mo

Página 15 - Option Board Compatibility

Page 22If the answer (and/or originate) connect baud rate is to be other than the DTE rate or if aparticular answer (and/or originate) connect baud r

Página 16 - Compatibility

Page 23Typical Host Modem Setup StringsThe following table will help configure the most popular host modems using MeterMate for DOS.In general, modem

Página 17 - Meter Installation

Page 24Figure 15 External Modem Connections for the DB-9 Cable.Figure 16 External Modem Connections for the RJ-11 Cable

Página 18 - Renewal Parts

Page 25RS-232 Simple Serial ModeRS-232 is used extensively for communications between computers and peripheral devices suchas the mouse, keyboard and

Página 19 - Other Renewal Parts:

Page 26RS-485 Simple Serial ModeRS-485 communications use differential voltage signals to improve on the noise immunity anddistance limitations of RS

Página 20 - Appendix

Page 27Figure 19 RS-485 Connections for the DB-9 Cable.Figure 20 RS-485 Connections for the RJ-11 Cable.

Página 21 - Baud Rate

Page 28Determining the Mode of an Installed kV RSXThe kV RSX option board is not detected by the meter in either RS-232 or RS-485 simple serialmodes.

Página 22

Page 29Using MeterMate Version 2.12 with the kV RSXMeterMate 2.12 can be used to build programs for both the kV Modem and the kV RSX optionboards. T

Página 23

Page 3Related Publications:GEH-5081 GE kV™ Vector Electricity Meter Installation, Operation, and Maintenance GuideGEH-5084 MeterMate™ for DOSReading

Página 24 - Page 24

Page 30External Modem ResetUnder the Call Answering options, the RSX Reset setup string defaults to z. This sends an ATZto the external modem to set

Página 25 - RS-232 Simple Serial Mode

Page 31Programming to use the Optional RJ-11 CableIf the program is being built for a kV RSX that uses a communications cable with the RJ-11(telephon

Página 26 - RS-485 Simple Serial Mode

Page 32IndexAA-base kV RSX kit, 18A-base meters, 6, 12, 13, 17Appendix, 20Bbattery, 8, 9, 14, 15battery holder, 14, 15battery test, 9Ccalibration, 17

Página 28

Page 4Table of ContentsINTRODUCTION 6KV RSX FEATURES, EXTERNAL MODEM MODE 6Data Rate 6Setup Strings 6Pulse/Tone 6Call Origination 7Introduction 7Prog

Página 29

Page 5MeterMate Software Compatibility 16TESTING METER CALIBRATION 17METER INSTALLATION 17Test Call 17RENEWAL PARTS 18kV RSX Kits 18S-Base kV RSX Ki

Página 30 - External Modem Reset

Page 6IntroductionThe kV RSX Communications Board is anoptional factory-supplied addition to the kV™Meter, or may be ordered in the form of aretrofit

Página 31 - Page 31

Page 7determined by contacting your localtelephone company.Call OriginationIntroductionThe kV™ Meter is capable of originating aphone call for the fo

Página 32 - Page 32

Page 8software on a particular day of the week,combination of days of the week, or everyday of the week at a single specified time.Using this option,

Página 33

Page 9Outage Retry AlgorithmIf the kV™ Meter outage call to the primaryphone number is unsuccessful the meter willdelay for 2 minutes, then attempt t

Comentários a estes Manuais