Black Box ME265C Especificações

Consulte online ou descarregue Especificações para Redes Black Box ME265C. Black Box ME265C Specifications [es] Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
CUSTOMER
SUPPORT
INFORMATION
Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX
FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746
Mail order: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018
Web site: www.blackbox.com • E-mail: [email protected]
AUGUST 2000
ME260A ME265C
ME260AE ME266C
ME261C ME267C
ME262C ME268C
ME263C
Modular Modem Eliminator
T
D
-1
P
W
R
R
D
-1
T
D
-2
R
D
-2
IN
T
.
C
O
N
V
.
E
L
A
S
T
IC
B
U
F
F
E
R
M
O
D
E
M
E
L
IM
IN
.
M
O
D
E
RATE
A
0 - 2.048 M
1 - 1.544 M
2 - 1.024 M
3 - 768 K
4 - 512 K
5 - 384 K
6 - 256 K
7 - 128 K
8 - 48 K
9 - 56 K
A - 64 K
B - 112 K
Vista de página 0
1 2 3 4 5 6 ... 49 50

Resumo do Conteúdo

Página 1 - Modular Modem Eliminator

CUSTOMERSUPPORTINFORMATIONOrder toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOXFREE technical support, 24 hours a day,

Página 2 - INDUSTRY CANADA

9CHAPTER 2: Introduction2. Introduction2.1 Functional DescriptionThe Modular Modem Eliminator is a universal interface converter that can be used to i

Página 3 - INSTRUCCIONES DE SEGURIDAD

10MODULAR MODEM ELIMINATORGeneral-Purpose Interface ModulesThe general-purpose interface modules are:• RS-232 Module (part number ME261C), EIA RS-232

Página 4 - NOM STATEMENT

11CHAPTER 2: Introduction2.2.3 OPERATINGMODESThe Modular Modem Eliminator has three operating modes, which are describedbelow.Interface-Converter Mode

Página 5

12MODULAR MODEM ELIMINATOR2.2.4 TIMINGOPTIONS FOR THEINTERFACEMODULESThe timing options offered by the Modular Modem Eliminator depend on two factors:

Página 6 - TABLE OF CONTENTS

13CHAPTER 2: Introduction• DTE—the interface module accepts clock signals for the receive and transmitpaths. Note that for the X.21 interface, the mod

Página 7

14MODULAR MODEM ELIMINATOR2.2.5 ITU G.703 64-KBPSCO-DIRECTIONALINTERFACEMODULE(ME266C)The 64-kbps co-directional interface specified by ITU G.703 incl

Página 8 - 1. Specifications

15CHAPTER 2: Specifications• LBT—the transmit clock is locked to the recovered receive clock (this mode is called “loopback timing”). Figure 2-4 shows

Página 9 - 1.7 Environment

16MODULAR MODEM ELIMINATOR2.2.6 ITU 1.544- AND2.048-MBPSINTERFACEMODULES(ME268CANDME267C)The ITU G.703 1.544-Mbps and 2.048-Mbps interface modules hav

Página 10 - 2. Introduction

17CHAPTER 2: Introduction2.2.7 GENERALCHARACTERISTICSThe Modular Modem Eliminator is a compact unit, intended for installation on adesktop or shelf. A

Página 11 - MODULAR MODEM ELIMINATOR

18MODULAR MODEM ELIMINATOR2.3 ApplicationsThis section provides a description of the functions performed by the ModularModem Eliminator. For illustrat

Página 12 - CHAPTER 2: Introduction

1FCC AND IC STATEMENTSFEDERAL COMMUNICATIONS COMMISSIONANDINDUSTRY CANADARADIO FREQUENCY INTERFERENCE STATEMENTSThis equipment generates, uses, and ca

Página 13

19CHAPTER 2: Introduction• Connection of a DTE to a 64 kbps co-directional G.703 1.544 Mbps or G.7031.048 Mbps network or DTE. In a typical applicatio

Página 14

20MODULAR MODEM ELIMINATOR2.3.2 INTERFACING BYGENERAL-PURPOSEMODULESFigure 2-8 shows a typical interface signals flow diagram for an interface convert

Página 15

21CHAPTER 2: Introduction2.3.3 INTERFACING WITH64-KBPSCO-DIRECTIONALINTERFACEMODULE(ME266C)Figure 2-9 shows a typical interface-signal flow diagram fo

Página 16 - CHAPTER 2: Specifications

22MODULAR MODEM ELIMINATOR2.3.4 INTERFACING WITHT1 ORE1 INTERFACEMODULEFigure 2-10 shows a typical interface-signal flow diagram for an interface conv

Página 17

23CHAPTER 2: Introduction2.3.5 MODEM-ELIMINATORAPPLICATIONSIn modem-eliminator applications, the Modular Modem Eliminator is used as areplacement for

Página 18

24MODULAR MODEM ELIMINATORTiming ModesWhen set for operation in the modem eliminator configuration, the ModularModem Eliminator offers two timing mode

Página 19 - 2.3 Applications

25CHAPTER 2: IntroductionFigure 2-13 shows the flow of the clock signals in this mode, as well as the flow of interface control signals.Figure 2-13. M

Página 20

26MODULAR MODEM ELIMINATOR2.4 Elastic-Buffer ApplicationsIn a typical elastic-buffer application, the Modular Modem Eliminator connectstwo DCEs that o

Página 21

27CHAPTER 2: IntroductionsFigure 2-15. Elastic buffer application (data, check, and interface control signals diagram).Internal ClockJ1J2DTE ModeDTE M

Página 22

28MODULAR MODEM ELIMINATOR3. Installation3.1 GeneralThe Modular Modem Eliminator is designed for installation as a desktop unit,however, a rackmount k

Página 23

2MODULAR MODEM ELIMINATORNORMAS OFICIALES MEXICANAS (NOM)ELECTRICAL SAFETY STATEMENTINSTRUCCIONES DE SEGURIDAD1. Todas las instrucciones de seguridad

Página 24

29CHAPTER 3: Installation3.2 Configuration Information3.2.1 GENERALBefore installing the Modem Eliminator, set the internal jumpers as explainedbelow.

Página 25

30MODULAR MODEM ELIMINATOR3.3.3 JUMPERLOCATION ANDFUNCTIONSModular Modem Eliminator jumpers are identified in Figure 3-2.Figure 3-2. Jumpers.CHASSIS

Página 26

31CHAPTER 3: InstallationNOTEThe functions of all the following jumpers are used only in the ME(modem eliminator) mode.CARRIER-2, JP5 (ME mode only)•

Página 27

32MODULAR MODEM ELIMINATOR3.2.4 SETTING THEJUMPERSCAUTIONDisconnect the unit from the power line before removing cover. Avoidadjusting, maintaining, a

Página 28 - CHAPTER 2: Introductions

33CHAPTER 3: InstallationFigure 3-4. G.703 interface modules.XMT TIMINGINT CLKEX CLKLBT CLKXMT TIMINGINT CLKEX CLKLBT CLKRATEXMT TIMING64 kbps128 kbps

Página 29 - 3. Installation

34MODULAR MODEM ELIMINATOR3.3 Configuring Interface Modules3.3.1 GENERAL-PURPOSEINTERFACEMODULESEach general-purpose interface module has a DTE/DCE se

Página 30 - 3.2 Configuration Information

35CHAPTER 3: Installation3.4 Installing Interface ModulesAs shown in Figure 3-5, the interface modules are held in place by two rails and arefastened

Página 31

36MODULAR MODEM ELIMINATOR3.5 Connecting the Cables3.5.1 CONNECTORLOCATIONFigure 3-6 identifies the connectors located on the rear panel of the Modula

Página 32

37CHAPTER 3: Installation3.5.4 GROUNDINGAny interruption of the protective (grounding) conductor (inside or outside the instrument) or disconnecting t

Página 33

38MODULAR MODEM ELIMINATOR4. Operation4.1 Front Panel Control and IndicatorsFigure 4-1. Front Panel.Table 4-1 lists the functions of the indicators an

Página 34

3NOM STATEMENT12. Precaución debe ser tomada de tal manera que la tierra fisica y la polarizacióndel equipo no sea eliminada.13. Los cables de la fuen

Página 35 - Configuring Interface Modules

39Table 4-1 (continued). Controls and indicators.No. Control or Indicator Function6, 7, 8 MODE indicators The indicator corresponding to the selectedo

Página 36

40MODULAR MODEM ELIMINATOR5. Troubleshooting5.1 Things To TryIn case a problem occurs, perform the following checks:• Check that the PWR indicator lig

Página 37 - 3.5 Connecting the Cables

41CHAPTER 5: Troubleshooting5.3 Shipping and PackagingIf you need to transport or ship your Modular Modem Eliminator:• Package it carefully. We recomm

Página 38

42MODULAR MODEM ELIMINATORAppendix A: Interface DataA.1 General-Purpose ModulesTable A-1 lists the line functions in the interface connectors of the M

Página 39 - 4. Operation

43Table A-1 (continued). Plug-in module’s interface connectors (line functions).Description Abbr. Direction EIA ITU V.35 V.36 ITU X.21of Signal RS-232

Página 40 - CHAPTER 4: Operation

44MODULAR MODEM ELIMINATORA.2 ITU G.703 Balanced Interface ModulesThe G.703 balanced interface modules have a 15-pin D-type female connector,wired as

Página 41 - 5. Troubleshooting

45Appendix B: Calculation of ElasticBuffer Over/Underflow RateB.1 GeneralAn important consideration in many applications is bit count integrity (BCI).

Página 42 - 5.3 Shipping and Packaging

46MODULAR MODEM ELIMINATORtransmitted. Other conditions of interest are multiplexed 64-kbps channelstransferred by digital multiplexors.When the digit

Página 45

4MODULAR MODEM ELIMINATORTRADEMARKSThe trademarks mentioned in this manual are the sole property of their owners.

Página 46 - Buffer Over/Underflow Rate

1000 Park Drive • Lawrence, PA 15055-1018 • 724-746-5500 • Fax 724-746-0746© Copyright 2000. Black Box Corporation. All rights reserved.

Página 47

5TABLE OF CONTENTSCONTENTSChapter Page1. Specifications...

Página 48

6MODULAR MODEM ELIMINATORCONTENTS (continued)Chapter Page3. Installation (continued)3.4 Installing of Interface Modules ...

Página 49

7CHAPTER 1: Specifications1. Specifications1.1 Interface Converter ModeInternal Data Rates—Up to 2048 kbpsTransmission Format—SynchronousTransmission

Página 50

8MODULAR MODEM ELIMINATOR1.6 Physical DataSize—ME260A, ME260AE: 1.7"H x 10.5"W x 9.6"D (4.4 x 2.7 x 2.4 cm);Interface Modules: 2.7"