Black Box SM702C Manual do Utilizador Página 201

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 200
198
PRO SWITCHING SYSTEM
timeTrigOpBusCodeEmit
Description: Code emitted over the inter-rack bus at the
time of the switching operation, set by the
‘timeTrigOpTime’ variable. You can SET and
GET the value of this variable.
Parameters: 0 (no code emitted) or 1 to 127
MIB Path: 1.3.6.1.4.1.509.1.9.1.8
iso(1).org(3).dod(6).internet(1).private(4).ent
erprises(1).Hadax(509).
IntelliSwitch2000(1).timeTrigOpTable(9).time
TrigOpEntry(1).
timeTrigOpBusCodeEmit(8)
Variable: 1.3.6.1.4.1.509.1.9.1.8.[timeTrigOpIndex]
where [timeTrigOpIndex] is a number (from 1
to 32) of a time-triggered switching operation
to which the code is assigned.
Example: Set code 50 to be emitted over the inter-rack
bus when the alarm(s) occur for time-triggered
switching operation 4.
Operation: Set
Variable: 1.3.6.1.4.1.509.1.9.1.8.4
Set Value: 50
timeTrigOpComment
Description: User comment for each time-triggered
switching operation. You can SET and GET the
value of this variable
Parameters: Up to 31 characters
MIB Path: 1.3.6.1.4.1.509.1.9.1.9
iso(1).org(3).dod(6).internet(1).private(4).ent
erprises(1).Hadax(509).
IntelliSwitch2000(1).timeTrigOpTable(9).time
TrigOpEntry(1).
timeTrigOpComment(9)
Vista de página 200
1 2 ... 196 197 198 199 200 201 202 203 204 205 206 ... 215 216

Comentários a estes Manuais

Sem comentários