Black Box Advanced Console Server Guia do Utilizador

Consulte online ou descarregue Guia do Utilizador para Servidores para consolas Black Box Advanced Console Server. Black Box Advanced Console Server User`s guide Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 392
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes

Resumo do Conteúdo

Página 1 - Advanced Console Server

BLACK BOX® Advanced Console Server Installation, Administration, and User’s GuideSoftware Version 2.6.0BLACK BOX® Corporation1000 Park DriveLawrence,

Página 2

Contentsx

Página 3

Web Manager for Administrators 70The following table illustrates the information that displays in the upper right corner of all Web Manager forms.Lo

Página 4

BLACK BOX® CS Installation, Administration, and User’s Guide 71 Logging Into the Web Manager Figure 4-2: Administrator > Web Manager Login Form2.

Página 5

Web Manager for Administrators 72Figure 4-3: Administrator > Multi Administrator Login Message3 Click the appropriate radio button and then click

Página 6

BLACK BOX® CS Installation, Administration, and User’s Guide 73 Overview of Administrative ModesFigure 4-4: Administrator > Security Advisory Mes

Página 7

Web Manager for Administrators 74Wizard ModeThe Wizard mode is designed to simplify the setup and configuration process by guiding the administrator

Página 8

BLACK BOX® CS Installation, Administration, and User’s Guide 75 Overview of Administrative Modesmenu bar in the Expert Mode to support more detailed

Página 9

Web Manager for Administrators 76Security Menu [Expert] Chapter 9Ports Menu [Expert] Chapter 10Administration Menu [Expert] Chapter 11Table 4-5: Adm

Página 10 - Contents

Chapter 5Configuring CS in Wizard ModeThere are six configuration steps displayed in the menu panel of the Web Manager in Wizard mode. The following

Página 11

Configuring CS in Wizard Mode 78Note: SSH root access is enabled when the security profile is set to “Moderate” or “Open”. If a “Secured” security

Página 12

BLACK BOX® CS Installation, Administration, and User’s Guide 79 Table 5-1: Wizard > Enabled services to access the CS under each security profile.

Página 13

TablesTable v-1: Typographic Conventions... 3Table v-2: Other Terms and Conventions...

Página 14

Configuring CS in Wizard Mode 80Table 5-3: Wizard > Enabled protocols for each security profile shown with a check mark.1-The Default security pr

Página 15

BLACK BOX® CS Installation, Administration, and User’s Guide 81 Serial Port Settings and Security ProfilesAll serial ports on CS units shipped from t

Página 16

Configuring CS in Wizard Mode 82T To Select or Configure a Security ProfileThe following procedure assumes you have installed a new CS at your site,

Página 17

BLACK BOX® CS Installation, Administration, and User’s Guide 83 Note: Your browser’s pop-up blocker should be disabled for this dialog box to appear.

Página 18

Configuring CS in Wizard Mode 84 Figure 5-5: Custom Security Profile Dialog BoxCaution: Take the required precautions to understand the potential im

Página 19

BLACK BOX® CS Installation, Administration, and User’s Guide 85 Note: It is not possible to continue working in the Web Manager without selecting a S

Página 20

Configuring CS in Wizard Mode 86In preparation to configure network settings collect the following information and proceed with the network configur

Página 21

BLACK BOX® CS Installation, Administration, and User’s Guide 87 Figure 5-7: Wizard > Step 2: Network Settings - DHCP enabled.T To configure the Ne

Página 22

Configuring CS in Wizard Mode 885. Select the “Next” button, or proceed to “Step 3: Port Profile”.Step 3: Port ProfileSelecting “Step 3: Port Profil

Página 23

BLACK BOX® CS Installation, Administration, and User’s Guide 89 The following table lists the parameters with the available options and a brief descr

Página 24

TablesxiiTable 4-2: Administrator > Web Manager Buttons... 70Table 4-3: Administrator > Options for Trying, Saving, and Re

Página 25 - Procedures

Configuring CS in Wizard Mode 90Expert mode provides additional options for custom configuration of serial ports. For example, to assign an alias to

Página 26

BLACK BOX® CS Installation, Administration, and User’s Guide 91 3. To change the parity, select “None,” “Odd” or “Even” from the “Parity” pull-down m

Página 27

Configuring CS in Wizard Mode 92 Figure 5-9: Wizard > Step 4:Access The Access form lists the currently defined Users and has “Add”, “Change Pass

Página 28

BLACK BOX® CS Installation, Administration, and User’s Guide 93 Figure 5-10:Wizard > Step 4: Access Add User Dialog BoxThe following table defines

Página 29

Configuring CS in Wizard Mode 94If you click the “Change Password” button, the following dialog box appears. Figure 5-11:Wizard > Step 4: Change

Página 30

BLACK BOX® CS Installation, Administration, and User’s Guide 95 b. To create an account with administrator privileges, select “Admin” from the “Group

Página 31 - Before You Begin

Configuring CS in Wizard Mode 963. Click “Change Password.” The “Change User Password” dialog box displays.4. Enter the new password in both fields,

Página 32

BLACK BOX® CS Installation, Administration, and User’s Guide 97 CS’s flash memory or on the hard disk of an external server, such as an NFS or Syslog

Página 33 - Related Documents

Configuring CS in Wizard Mode 98Figure 5-14:Wizard > Step 5: Data Buffering [Remote]The following table provides description for each field wheth

Página 34 - BLACK BOX® firmware Upgrades

BLACK BOX® CS Installation, Administration, and User’s Guide 99 Note: Make sure that enough disk space is available to store the files in the locatio

Página 35 - Introduction

BLACK BOX® CS Installation, Administration, and User’s Guide xiiiTable 8-2: Expert > Host Settings Form Fields ... 155Tabl

Página 36 - Overview

Configuring CS in Wizard Mode 100Note: You can perform advanced configuration in Expert mode including the option of setting up data buffering separ

Página 37

BLACK BOX® CS Installation, Administration, and User’s Guide 101 a. In the “NFS File Path” field, enter the pathname for the mount point of the direc

Página 38 - Power Supply

Configuring CS in Wizard Mode 102The form appears as shown in the following figure.Figure 5-15:Wizard > Step 6: System LogNote: To configure sysl

Página 39 - Web Manager

BLACK BOX® CS Installation, Administration, and User’s Guide 103 The System Log form displays.2. From the Facility Number drop-down menu, select the

Página 40 - Security

Configuring CS in Wizard Mode 104Network Menu [Expert] Chapter 8, “Network Menu & FormsSecurity Menu [Expert] Chapter 9, “Security Menu & Fo

Página 41

Chapter 6Configuring the CS in Expert ModeThis chapter provides an overview of configuring the CS Web Manager in Expert Mode. The following chapters

Página 42

Configuring the CS in Expert Mode 106These forms are identified by their tabs. Select the tab to access the desired form.Figure 6-1: Expert Mode Scre

Página 43 - Packet Filtering on CS

BLACK BOX® CS Installation, Administration, and User’s Guide 107 Mapping of the Expert Mode Menus and FormsMapping of the Expert Mode Menus and Form

Página 44

Configuring the CS in Expert Mode 108Description of Forms in Expert ModeThe following table briefly describes the functionality of each menu and the

Página 45

BLACK BOX® CS Installation, Administration, and User’s Guide 109 Description of Forms in Expert ModeTable 6-3: Expert > NetworkMenu Selection Use

Página 46

TablesxivTable 10-2: Expert > Console Connection Protocols... 245Table 10-3: Expert > Terminal Server (TS) Connected Protocol

Página 47

Configuring the CS in Expert Mode 110Static RoutesTo manually add routes. Static routes are a very quick and effective way to route data from one sub

Página 48

BLACK BOX® CS Installation, Administration, and User’s Guide 111 Description of Forms in Expert ModeVirtual PortsPerform Clustering. One CS can be u

Página 49

Configuring the CS in Expert Mode 112Time/DateSet the timezone and configure the system’s Date and Time.Network Time Protocol (NTP) can also be used.

Página 50

BLACK BOX® CS Installation, Administration, and User’s Guide 113 Description of Forms in Expert Mode

Página 51 - Syslog Servers

Configuring the CS in Expert Mode 114

Página 52 - facility

Chapter 7Applications Menu & FormsThis Chapter describes the “Applications” menu and the related forms. The following table provides a descriptio

Página 53 - CS and Power Management

Applications Menu & Forms 116ApplicationsUnder “Applications” in Expert mode, five options appear in the left menu panel as shown in the followin

Página 54 - Configuring Power Management

BLACK BOX® CS Installation, Administration, and User’s Guide 117 ApplicationsFigure 7-2: Expert > Applications > Connect FormUsing the “Connec

Página 55

Applications Menu & Forms 118 Figure 7-3: Expert > SSH session Java Applet Note: SSH root access is enabled when the security profile is set t

Página 56 - Options for Managing Power

BLACK BOX® CS Installation, Administration, and User’s Guide 119 ApplicationsFigure 7-4: Expert > Serial Port Java AppletNote the difference betw

Página 57 - Chapter 2

FiguresFigure 1-1: CS Front with PCMCIA Card Slots... 8Figure 1-2: CS Back with Connectors ...

Página 58 - Shipping Box Contents

Applications Menu & Forms 120A Java applet viewer appears. If your security profile is set to “Moderate” or “Open” you receive a “root” prompt, o

Página 59

BLACK BOX® CS Installation, Administration, and User’s Guide 121 ApplicationsThe following table provides links to description and procedures for th

Página 60

Applications Menu & Forms 122Figure 7-6: Expert > Applications > IPDU Power Mgmt. > Outlets ManagerThe following table illustrates what

Página 61

BLACK BOX® CS Installation, Administration, and User’s Guide 123 Applications Figure 7-7: Expert > Outlets Manager IconsClicking the Edit button

Página 62

Applications Menu & Forms 1244. To momentarily power an outlet off and then on again, click the adjacent “Cycle” button.5. To change the outlet’s

Página 63

BLACK BOX® CS Installation, Administration, and User’s Guide 125 Applicationsconfigured for syslogging, an alarm buzzer, and over current protection

Página 64 - Basic Installation Procedures

Applications Menu & Forms 126Table 7-4: Expert > View IPDUs Unit InformationT To View and Reset IPDU Information1. Go to Applications > IPD

Página 65 - Making an Ethernet Connection

BLACK BOX® CS Installation, Administration, and User’s Guide 127 ApplicationsUsers ManagerOn the “Users Manager” form under Applications > IPDU P

Página 66

Applications Menu & Forms 128When a user is added, their name is added to the list on the Users Manager form, as shown in the following figure.T

Página 67 - Network Parameters

BLACK BOX® CS Installation, Administration, and User’s Guide 129 ApplicationsConfigurationOn the “Configuration” form under Applications > IPDU P

Página 68

Figuresxvi... 64Figure 4-1: Administrator > Web Manager Buttons..

Página 69 - To Change the root password

Applications Menu & Forms 130Figure 7-12: Expert > Applications > IPDU Power Mgmt. > ConfigurationNote: The number of amps shown in the

Página 70

BLACK BOX® CS Installation, Administration, and User’s Guide 131 Applications3. Click “apply changes.” Software Upgrade [for the AlterPath PM]On the

Página 71

Applications Menu & Forms 132TTo Download AlterPath PM SoftwareYou can use this procedure to download the AlterPath PM software.1. On a computer

Página 72

BLACK BOX® CS Installation, Administration, and User’s Guide 133 ApplicationsThis procedure requires the following:• A more-recent version of the Al

Página 73 - To Select a Security Profile

Applications Menu & Forms 134Figure 7-14: Expert > Applications > IPDU Multi-Outlet CtrlWhether the power supplies are connected to the sam

Página 74

BLACK BOX® CS Installation, Administration, and User’s Guide 135 ApplicationsFigure 7-15: Expert > Applications > Multi-Outlet Ctrl [not confi

Página 75

Applications Menu & Forms 136Figure 7-16: Expert > Applications > Multi-Outlet Control IconsThe icons in the first line of each group are d

Página 76 - Installing PCMCIA Cards

BLACK BOX® CS Installation, Administration, and User’s Guide 137 ApplicationsNote: Only one outlet needs to be powered on or unlocked in order for t

Página 77 - Connecting AlterPath PM IPDUs

Applications Menu & Forms 138a. Click the yellow light bulb icon adjacent to the group name once to turn all of the outlets off.All of the outlet

Página 78

BLACK BOX® CS Installation, Administration, and User’s Guide 139 Applications1. Go to Applications > IPDU Multi-Outlet Ctrl.2. Make sure that all

Página 79 - Web Manager for Regular Users

BLACK BOX® CS Installation, Administration, and User’s Guide xviiManager... 124Figur

Página 80

Applications Menu & Forms 140 Figure 7-18:Expert > IPMI Power Mgmt. “Add/Edit IPMI Device” Dialog Boxes After you fill out the fields or make

Página 81 - Form area

BLACK BOX® CS Installation, Administration, and User’s Guide 141 Applicationsauthorized to connect to serial ports can perform IPMI power management

Página 82

Applications Menu & Forms 142TTo Delete, Add, or Edit an IPMI Device to Enable or Disable IPMI Power Management1. Go to Applications> IPMI Pow

Página 83 - Connect to CS

BLACK BOX® CS Installation, Administration, and User’s Guide 143 Applicationsf. Enter a password for administering the remote device in the “Passwor

Página 84 - Connect to Serial Ports

Applications Menu & Forms 144Figure 7-20: Expert > Serial Port > Power Management > Enable Power Management 4. Click the “Add” buttonThe

Página 85 - To Close a Telnet Session

BLACK BOX® CS Installation, Administration, and User’s Guide 145 ApplicationsThe power management port and the specified outlet numbers display on t

Página 86

Applications Menu & Forms 146TTo enable IPMI Power Management of an IPMI device connected to the currently-selected port1. Check the checkbox ne

Página 87

BLACK BOX® CS Installation, Administration, and User’s Guide 147 Applicationsconfigured as a local terminal launches a session directly on the CS wi

Página 88

Applications Menu & Forms 148For example, you can create a menu called “SSH to Servers” with options that launch SSH connections to several serve

Página 89

BLACK BOX® CS Installation, Administration, and User’s Guide 149 Applications5. Click “apply changes.”

Página 90

FiguresxviiiBox... 149Figure 7-26: Expert > Terminal Profile Menu Example.

Página 91

Applications Menu & Forms 150

Página 92

Chapter 8Network Menu & FormsThis Chapter describes the “Network” menu and the related forms. The following table provides a description of the l

Página 93

Network Menu & Forms 152NetworkHost SettingsWhen you select Network > Host Settings the following form appears.Figure 8-1: Expert > Network

Página 94

BLACK BOX® CS Installation, Administration, and User’s Guide 153 NetworkIf the “DHCP” is not enabled, then other options appear on the form as shown

Página 95 - Chapter 4

Network Menu & Forms 154Console BannerA text string designed to appear on the console upon logging into and exiting from a port as a way to verif

Página 96 - BLACK BOX® Web Manager

BLACK BOX® CS Installation, Administration, and User’s Guide 155 NetworkCaution: If you have set IP Filtering rules before bonding is activated, the

Página 97

Network Menu & Forms 156The console banner appears on the console upon logging into and exiting from a port as a way to verify or identify the pa

Página 98 - Buttons and CS Information

BLACK BOX® CS Installation, Administration, and User’s Guide 157 NetworkSyslogWhen Network > Syslog is selected the form shown in the following f

Página 99

Network Menu & Forms 158The top field on the form “CAS Ports Facility” is used to tell CS where to send syslog messages. • You can specify a faci

Página 100 - Logging Into the Web Manager

BLACK BOX® CS Installation, Administration, and User’s Guide 159 NetworkFigure 8-4: Expert > Network > PCMCIA ManagementYou can use the PCMCIA

Página 101

BLACK BOX® CS Installation, Administration, and User’s Guide xixFigure 8-18: Expert > “New/Mod SNMP v1 v2 Configuration” Dialog Box ...

Página 102

Network Menu & Forms 160T To Configure a PCMCIA Card1. Go to Network > PCMCIA Management.The PCMCIA Management form appears.2. Insert the card

Página 103

BLACK BOX® CS Installation, Administration, and User’s Guide 161 Network6. Select the desired PCMCIA card type from the pull-down menu.7. Follow the

Página 104 - Expert Mode

Network Menu & Forms 162Figure 8-5: Expert > PCMCIA Modem Card Configuration Dialog BoxThe following table provides a brief description of the

Página 105

BLACK BOX® CS Installation, Administration, and User’s Guide 163 NetworkFigure 8-6: Expert > PCMCIA Modem Card Configuration Dialog Box -PPPIf yo

Página 106

Network Menu & Forms 164TTo Configure a Modem PCMCIA Card1. Install the modem card and select “Modem” from the pull-down menu on the PCMCIA Manag

Página 107 - Configuring CS in Wizard Mode

BLACK BOX® CS Installation, Administration, and User’s Guide 165 NetworkFigure 8-8: Expert > ISDN PCMCIA Card Configuration Dialog BoxThe followi

Página 108 - Default Security Profile

Network Menu & Forms 1662. Enter an IP address in the “Local IP” field, if desired.By default, the IP address of the CS is used. Only change the

Página 109

BLACK BOX® CS Installation, Administration, and User’s Guide 167 NetworkFigure 8-9: Expert > GSM PCMCIA Card Configuration Dialog BoxWhen the “C

Página 110 - User Configurable

Network Menu & Forms 168The following table provides a brief description of the fields available in the GSM dialog box.Table 8-5: Expert > For

Página 111

BLACK BOX® CS Installation, Administration, and User’s Guide 169 Networka. Check the “Call Back” check box. The “Phone Number” field appears on the

Página 112

© 2005 BLACK BOX® Corporation, all rights reservedInformation in this document is subject to change without notice.BLACK BOX® is the registered tradem

Página 113

FiguresxxFigure 8-33: Firewall Configuration “Add Rule” and “Edit Rule” UDP Protocol Fields ... 196Figur

Página 114

Network Menu & Forms 170TTo Configure an Ethernet PCMCIA Card1. Install the Ethernet card and select “Ethernet” from the pull-down menu on the PC

Página 115 - Step 2: Network Settings

BLACK BOX® CS Installation, Administration, and User’s Guide 171 NetworkFigure 8-12: Expert > PCMCIA Compact Flash/Hard Disk Configuration Dial

Página 116

Network Menu & Forms 172The “Enable” checkbox appears on the Slot dialog box.2. Click the “Enable” checkbox. The “Use for data buffering” checkbo

Página 117

BLACK BOX® CS Installation, Administration, and User’s Guide 173 NetworkTable 8-8: Expert > Form Fields for a Wireless LAN Card.T To Configure a

Página 118 - Step 3: Port Profile

Network Menu & Forms 174Configuring a CDMA PCMCIA CardYou can use the “PCMCIA Management” form under “Network” to configure a CDMA PCMCIA card. W

Página 119

BLACK BOX® CS Installation, Administration, and User’s Guide 175 NetworkTTo Configure a CDMA PCMCIA Card1. Install the CDMA card and select “CDMA” f

Página 120 - Flow Control” pull-down menu

Network Menu & Forms 176Ejecting a PCMCIA CardUse the “Eject” button on the PCMCIA management form to eject any PCMCIA card before physically eje

Página 121 - Step 4: Access

BLACK BOX® CS Installation, Administration, and User’s Guide 177 NetworkFigure 8-15: Expert > Network > VPN ConnectionsYou can use the form to

Página 122

Network Menu & Forms 178Figure 8-16: Expert > VPN “New/Modify Connection” Dialog Box The remote gateway is referred to as the Remote or “Right

Página 123

BLACK BOX® CS Installation, Administration, and User’s Guide 179 NetworkTable 8-10: Expert > Field and Menu Options for Configuring a VPN Connect

Página 124 - To Add a User

BLACK BOX® CS Installation, Administration, and User’s Guide xxiFigure 9-10: Expert > Administration > Time/Date ... 226Figur

Página 125 - To Change a Password

Network Menu & Forms 180TTo Configure VPNTo enable VPN, make sure that IPSec is enabled through the security profile section. 1. Go to Network &g

Página 126 - Step 5: Data Buffering

BLACK BOX® CS Installation, Administration, and User’s Guide 181 Networke. If “RSA Key” is selected, generate the key for the CS (left host) and fin

Página 127

Network Menu & Forms 182Figure 8-17: Expert > Network > SNMPYou can use this form to enable notifications about significant events or traps

Página 128

BLACK BOX® CS Installation, Administration, and User’s Guide 183 NetworkTable 8-11: Expert > Fields and Menu Options for SNMP ConfigurationClicki

Página 129

Network Menu & Forms 184Figure 8-18: Expert > “New/Mod SNMP v1 v2 Configuration” Dialog BoxClicking the “Add” or “Edit” buttons under “SNMPv3

Página 130 - To Configure Data Buffering

BLACK BOX® CS Installation, Administration, and User’s Guide 185 NetworkThe “New/Modify SNMP Daemon Configuration” dialog box appears.3. To edit any

Página 131 - Step 6: System Log

Network Menu & Forms 186Table 8-12: Expert > Tasks for Configuring SNMPFirewall ConfigurationFirewall configuration, also known as IP filterin

Página 132 - To Add a Syslog Server

BLACK BOX® CS Installation, Administration, and User’s Guide 187 NetworkEach entry in the list on the Firewall Configuration form represents a chain

Página 133 - To Delete a Syslog Server

Network Menu & Forms 188Figure 8-22:Firewall Configuration “User-defined Chain” Message“Delete” ButtonIf one of the user-defined chains is select

Página 134

BLACK BOX® CS Installation, Administration, and User’s Guide 189 Network Figure 8-24:Expert > Firewall Configuration “Add Chain” Dialog BoxAdding

Página 135 - Chapter 6

FiguresxxiiFigure 10-13: Connection Protocols > Terminal Server ... 253Figure 10-14: Expert > Ports > Physical Ports > Mod

Página 136

Network Menu & Forms 190 Figure 8-26:Firewall Configuration “Edit Rules for chain_name” Buttons• Pressing the “Add” button opens the “Add Rule” d

Página 137 - Ports Administration

BLACK BOX® CS Installation, Administration, and User’s Guide 191 NetworkFor example, you select “DROP” as the target action from the “Target” drop-d

Página 138

Network Menu & Forms 192ProtocolYou can select a protocol for filtering. The “Protocol” pull-down menu is shown in the following figure.Figure 8-

Página 139

BLACK BOX® CS Installation, Administration, and User’s Guide 193 NetworkFigure 8-32:Firewall Configuration “Add Rule” and “Edit Rule” TCP Protocol F

Página 140

Network Menu & Forms 194Figure 8-33:Firewall Configuration “Add Rule” and “Edit Rule” UDP Protocol FieldsThe following table defines the fields i

Página 141

BLACK BOX® CS Installation, Administration, and User’s Guide 195 NetworkFigure 8-34:Firewall Configuration “Add Rule” and “Edit Rule” ICMP Type Menu

Página 142

Network Menu & Forms 196Input Interface, Output Interface, and FragmentsIf an interface (such as eth0 or eth1) is entered in the “Input Interface

Página 143

BLACK BOX® CS Installation, Administration, and User’s Guide 197 NetworkLOG TargetIf you select “LOG” from the “Target” field, the fields and menus

Página 144

Network Menu & Forms 198REJECT TargetIf REJECT is selected from the Target pull-down menu, the following pull-down menu appearsFigure 8-37:Firewa

Página 145 - Applications Menu & Forms

BLACK BOX® CS Installation, Administration, and User’s Guide 199 NetworkNote: The packets are matched (using tcp flags and appropriate reject type)

Página 146 - Applications

BLACK BOX® CS Installation, Administration, and User’s Guide xxiiiFigure 10-33: Expert > Ports > Virtual Ports > New/Modify Port Dialog Box

Página 147

Network Menu & Forms 200Note: User-defined chains cannot be edited. If you want to rename a chain you added, delete it and create a new one.1. Go

Página 148

BLACK BOX® CS Installation, Administration, and User’s Guide 201 Network2. Select the chain to which you want to add a rule from Chain list, and the

Página 149 - To Connect to the CS

Network Menu & Forms 202Figure 8-38: Expert > Network > Host TablesT To Define the CS’s IP Address and Hostname1. Go to Network > Host T

Página 150 - IPDU Power Mgmt

BLACK BOX® CS Installation, Administration, and User’s Guide 203 NetworkFigure 8-39: Expert > Network > Static RoutesClicking the “Edit” or “A

Página 151 - Outlets Manager

Network Menu & Forms 204The following figure shows the fields and menus that appear when the “Network” route type is selected from the “Route” pu

Página 152

BLACK BOX® CS Installation, Administration, and User’s Guide 205 NetworkFigure 8-42: Expert > Static Routes “Add” and “Edit” Dialog Boxes - Host

Página 153 - Power Outlets

Network Menu & Forms 2063. If you selected “Network, do the following steps.a. Enter the IP address of the destination network in the “Network IP

Página 154 - View IPDUs Info

Chapter 9Security Menu & FormsThis Chapter describes the “Security” menu and the related forms. The following table provides a description of the

Página 155

Security Menu & Forms 208Users and GroupsUsers and Groups form allows you to do the following tasks:• Set up user access to the CS Web Manager• A

Página 156

BLACK BOX® CS Installation, Administration, and User’s Guide 209 • Add users to a group• Delete users from a groupAdding a UserIf you click the “Add”

Página 158

Security Menu & Forms 210Adding a GroupIf you click the “Add” button on the Security > Users and Groups form under the “Group List”, the follo

Página 159 - Configuration

BLACK BOX® CS Installation, Administration, and User’s Guide 211 3. Enter the name in the “User Name” field.4. Enter the password in the “Password” a

Página 160 - Current Protection for IPDUs

Security Menu & Forms 212The Users & Groups form displays.2. Under the list of groups, click “Add.”The “Add Group” dialog box displays.3. Ent

Página 161

BLACK BOX® CS Installation, Administration, and User’s Guide 213 Figure 9-4: Expert > Security > Active Ports Sessions The Active Ports Session

Página 162

Security Menu & Forms 214T To View, Kill, or Refresh Active User Sessions1. Go to Security > Active Ports Sessions in Expert mode.The Active P

Página 163 - IPDU Multi-Outlet Ctrl

BLACK BOX® CS Installation, Administration, and User’s Guide 215 Figure 9-5: Expert > Security > AuthenticationYou can use the Authentication

Página 164

Security Menu & Forms 216Figure 9-6: Expert > Security > Authentication > AuthType Form Any authentication method selected for CS is use

Página 165 - Power Management Icons

BLACK BOX® CS Installation, Administration, and User’s Guide 217 The following is a summary of the things you need to know about setting up authentic

Página 166

Security Menu & Forms 218TTo Configure a RADIUS Authentication ServerPerform the following procedure to configure a RADIUS authentication server

Página 167 - Power States

BLACK BOX® CS Installation, Administration, and User’s Guide 219 Group Authorization on RADIUSGroup information retrieval from a RADIUS authenticatio

Página 168

ProceduresTTo check Java Plug-in Support in the Browser... 35TTo Install JRE Version 1.4.2 or later and Registe

Página 169 - IPMI Power Management

Security Menu & Forms 2202Fill in the form according to your local TACACS+ server configuration.3 To apply “Authorization” in addition to authent

Página 170

BLACK BOX® CS Installation, Administration, and User’s Guide 221 configuration procedures for a TACACS+ authentication server refer to the CS Command

Página 171 - /etc/IPMIServer.conf files

Security Menu & Forms 222Figure 9-9: Expert > Security > Authentication > LDAP2. Supply the IP address of the LDAP server in the “LDAP S

Página 172

BLACK BOX® CS Installation, Administration, and User’s Guide 223 authorization through CS. To see the configuration procedures for an LDAP authentica

Página 173 - Management

Security Menu & Forms 224iv. Enter an optional alias in the “Alias” field.2. Make sure that time, date, and timezone settings are synchronized on

Página 174

BLACK BOX® CS Installation, Administration, and User’s Guide 225 Figure 9-11:Expert > Security > Authentication > Kerberos5. Fill in the for

Página 175 - Connected To a Serial Port

Security Menu & Forms 226Figure 9-12:Expert > Security > Authentication > NIS2. Fill in the form according to your configuration of the

Página 176 - Terminal Profile Menu

BLACK BOX® CS Installation, Administration, and User’s Guide 227 A Security Profile consists of a set of parameters that can be configured in order t

Página 177

Security Menu & Forms 228The following tables illustrate the properties for each of the Security Profiles. The enabled services in each profile i

Página 178

BLACK BOX® CS Installation, Administration, and User’s Guide 229 Table 9-7: Expert > Enabled protocols for each security profile shown with a chec

Página 179 - 5. Click “apply changes.”

ProceduresxxviTTo Log Into the Web Manager...72TTo Select or Configure a Security Prof

Página 180

Security Menu & Forms 230Serial Port Settings and Security ProfilesAll serial ports on CS units shipped from the factory are disabled by default.

Página 181 - Network Menu & Forms

BLACK BOX® CS Installation, Administration, and User’s Guide 231 • If the serial port connection protocol is incompatible with the selected security

Página 182 - Host Settings

Security Menu & Forms 232Figure 9-17: Security Advisory Dialog BoxNote: Your browser’s pop-up blocker should be disabled for this dialog box to a

Página 183

BLACK BOX® CS Installation, Administration, and User’s Guide 233 Figure 9-18:Wizard > Step 1: Security Profile Form4. Select a pre-defined Securit

Página 184

Security Menu & Forms 234Figure 9-19: Custom Security Profile Dialog BoxCaution: Take the required precautions to understand the potential impact

Página 185

BLACK BOX® CS Installation, Administration, and User’s Guide 235 Note: It is not possible to continue working in the Web Manager without selecting a

Página 186

Security Menu & Forms 236Security CertificatesCS generates its own self-signed SSL certificate for HTTPS using OpenSSL. Note: It is highly recomm

Página 187

Chapter 10Ports Menu & FormsThis Chapter describes the “Ports” menu and the related forms. The following table provides a description of the left

Página 188 - PCMCIA Management

Ports Menu & Forms 238The Ports section of CS configuration in Expert Mode provides the following menu choices:• Physical Ports – Allows you to v

Página 189

BLACK BOX® CS Installation, Administration, and User’s Guide 239 Using the forms described in the following sections, you can perform custom configur

Página 190 - To Configure a PCMCIA Card

BLACK BOX® CS Installation, Administration, and User’s Guide xxviiTTo Configure Host Settings [Expert]...

Página 191

Ports Menu & Forms 240tabsFigure 10-3: Expert > Ports > Physical Ports > “Modify ... Ports ” Tab OptionsT To Select One or More Serial

Página 192

BLACK BOX® CS Installation, Administration, and User’s Guide 241 T To Enable or Disable Serial Ports1 Go to Ports > Physical Ports, and select a

Página 193

Ports Menu & Forms 242Figure 10-4: Expert > Ports > Physical Ports > General FormThe General form allows you to define general port sett

Página 194

BLACK BOX® CS Installation, Administration, and User’s Guide 243 Console Access Server (CAS) Profile Connection ProtocolsWhen a serial port is connec

Página 195

Ports Menu & Forms 244Selecting the appropriate connection protocol on the Ports > Physical Ports > General form is part of defining the TS

Página 196 - Configuring a GSM PCMCIA Card

BLACK BOX® CS Installation, Administration, and User’s Guide 245 Bidirectional Telnet ProtocolBidirectional Telnet protocol can be selected from the

Página 197

Ports Menu & Forms 246from a terminal window using the menush_cfg command. You should specify the bidirectional shell command, /bin/menush in the

Página 198

BLACK BOX® CS Installation, Administration, and User’s Guide 247 Figure 10-5: Expert > Ports > Physical Ports > Console Connection Active Ta

Página 199

Ports Menu & Forms 248Figure 10-7:Connection Protocols > Console4. If you want to change any of the other current settings, see "To Confi

Página 200 - Disk Drive

BLACK BOX® CS Installation, Administration, and User’s Guide 249 The General form appears with the number(s) of the selected port(s) next to the Done

Página 201 - Hard Disk Drive

ProceduresxxviiiTTo Select One or More Serial Ports... 242T To Enable or Disable Serial Ports...

Página 202

Ports Menu & Forms 2504. If you want to change any of the other current settings, see "To Configure Serial Port Settings to Match the connec

Página 203

BLACK BOX® CS Installation, Administration, and User’s Guide 251 The General form appears with the number(s) of the selected port(s) next to the Done

Página 204

Ports Menu & Forms 2524. To configure a terminal to automatically connect to CS, do the following steps.a. Select “Local Terminal” from the “Conn

Página 205

BLACK BOX® CS Installation, Administration, and User’s Guide 253 The General form appears with the number(s) of the selected port(s) next to the Done

Página 206 - VPN Connections

Ports Menu & Forms 2544. If you want to change any of the other current settings, see "To Configure Serial Port Settings to Match the connec

Página 207

BLACK BOX® CS Installation, Administration, and User’s Guide 255 Figure 10-18: Expert > Ports > Physical Ports > Power Management Connectio

Página 208

Ports Menu & Forms 2565. Select an access method to the IPDU from the “Allow Access by” drop-down menu. The options are SSH, Telnet, or SSH and T

Página 209

BLACK BOX® CS Installation, Administration, and User’s Guide 257 8. If you are finished, click “Done.”9. Click “apply changes.”T To Associate an Alia

Página 210 - To Configure VPN

Ports Menu & Forms 258Figure 10-21: Expert > Ports > Physical Ports > Serial Port Settings2. To change the baud rate, select an option f

Página 211

BLACK BOX® CS Installation, Administration, and User’s Guide 259 7. To change whether the “DCD (Data Carrier Detect) State” is disregarded or not, se

Página 212

BLACK BOX® CS Installation, Administration, and User’s Guide xxixTTo Back Up or Restore the Configuration Files using an FTP Server...314TTo Back Up

Página 213

Ports Menu & Forms 260The following table describes the menu and fields on the Access form.Table 10-5: Expert > Access Form Fields Field Descr

Página 214 - To Configure SNMP

BLACK BOX® CS Installation, Administration, and User’s Guide 261 T To Configure User Access to Serial PortsUse this procedure if you want to specify

Página 215

Ports Menu & Forms 262defined in case the first authentication level fails. See the following table on authentication methods and fallback mechan

Página 216 - Firewall Configuration

BLACK BOX® CS Installation, Administration, and User’s Guide 263 T To Configure a Serial Port Login Authentication MethodThis procedure configures an

Página 217

Ports Menu & Forms 264The following table lists the procedures that apply to each authentication method. Data BufferingUnder Ports > Physical

Página 218

BLACK BOX® CS Installation, Administration, and User’s Guide 265 There are different fields on this form depending on whether one or both options are

Página 219

Ports Menu & Forms 266Mode (Local Destination) circular or linear. In circular mode, data is written into the specified local data file until the

Página 220

BLACK BOX® CS Installation, Administration, and User’s Guide 267 T To Configure Data Buffering for Serial PortsPerform this procedure if you want to

Página 221

Ports Menu & Forms 268• Show data buffering file only• Show without the erase options 4. If you checked “Buffer to Syslog,” perform the following

Página 222

BLACK BOX® CS Installation, Administration, and User’s Guide 269 Figure 10-25:Expert > Port > Physical Ports >Multi UserThe Multi User form

Página 223

ContentsBefore You Begin ...1Audience ...

Página 224

Proceduresxxx

Página 225 - Type Menu Options

Ports Menu & Forms 270The following table describes the options from the “Allow Multiple Sessions” pull-down menu.T To Configure Multiple Session

Página 226

BLACK BOX® CS Installation, Administration, and User’s Guide 271 3. To allow or to prevent multiple sessions, select an option from the “Allow Multip

Página 227

Ports Menu & Forms 272You can use this form to make it possible for a user who is connected to a device through the selected serial port to perfo

Página 228

BLACK BOX® CS Installation, Administration, and User’s Guide 273 Enable IPMI on this portCheck mark to enable IPMI on the selected port(s).IPMI Key (

Página 229 - To Edit a Chain

Ports Menu & Forms 274Power management while connected to a port is possible only when one or both of the following conditions are true.• The dev

Página 230 - To Add a Rule

BLACK BOX® CS Installation, Administration, and User’s Guide 275 2. To enable Power Management of a device connected to the current port and plugged

Página 231 - Host Table

Ports Menu & Forms 2764. Click “Done.”5. Click “apply changes.”T To Configure a User for IPDU Power Management While Connected To a Serial PortPe

Página 232 - Static Routes

BLACK BOX® CS Installation, Administration, and User’s Guide 277 4. Enter a valid username or groupname in the “New User/Group” field, and click “Add

Página 233

Ports Menu & Forms 278Table 10-12: Expert > Ports > Physical Ports > Other Form FieldsField Name DefinitionTCP PortThe TCP Port number f

Página 234

BLACK BOX® CS Installation, Administration, and User’s Guide 279 T To Configure TCP Port Number, STTY Options, Break Interval, and the Login Banner f

Página 235

Before You BeginThis installation, administration, and user’s guide provides background information and procedures for installing, configuring, and ad

Página 236

Ports Menu & Forms 2803. To change the port number for the serial port, enter another number in the “TCP Port” field.4. To assign a name to the p

Página 237 - Security Menu & Forms

BLACK BOX® CS Installation, Administration, and User’s Guide 281 3. To change the port number used to access the serial port, enter another number in

Página 238 - Users and Groups

Ports Menu & Forms 282Figure 10-32: Expert > Ports > Virtual PortsThe virtual ports form allows you to perform clustering of CS units. The

Página 239 - Adding a User

BLACK BOX® CS Installation, Administration, and User’s Guide 283 Figure 10-33: Expert > Ports > Virtual Ports > New/Modify Port Dialog BoxTh

Página 240 - Adding a Group

Ports Menu & Forms 284Once you have configured the “Slave” CS unit and defined the cluster parameters, the slave serial ports and the connected d

Página 241 - To Add a Group

BLACK BOX® CS Installation, Administration, and User’s Guide 285 Figure 10-34: Expert > Applications > Connect > Serial pull-down menuT To C

Página 242 - Active Ports Sessions

Ports Menu & Forms 286This is the first port number on the master, after the last port number on the master. 4. Enter the “Local IP” address. Thi

Página 243

BLACK BOX® CS Installation, Administration, and User’s Guide 287 Figure 10-36: Expert > Ports > Virtual Ports > New/Modify > Port Names D

Página 244 - Authentication

Ports Menu & Forms 288Figure 10-37: Expert > Ports > Ports Status (Read-Only) The information in the following table is available in the Po

Página 245

BLACK BOX® CS Installation, Administration, and User’s Guide 289 Figure 10-38: Expert > Ports > Port Statistics (Read-Only)The following inform

Página 246

Before You Begin23: Web Manager for Regular UsersDescribes how authorized users use the Web Manager to access devices that are connected to ports on t

Página 247

Ports Menu & Forms 290ParityError checking bit appended to a data packet.A method of checking the accuracy of transmitted characters. Parity is u

Página 248

Chapter 11Administration Menu & FormsThis Chapter describes the “Administration” menu and the related forms. The following table provides a descr

Página 249 - Group Authorization on RADIUS

Administration Menu & Forms 292System InformationSelecting Administration > System information in Expert mode brings up the following informat

Página 250

BLACK BOX® CS Installation, Administration, and User’s Guide 293 Figure 11-1: Expert > Administration > System InformationYou can use the form

Página 251

Administration Menu & Forms 294Table 11-2: System InformationInformationParametersSystem• Kernel Version• Current Date•Up Time• Power Supply Stat

Página 252 - Group Authorization on LDAP

BLACK BOX® CS Installation, Administration, and User’s Guide 295 T To View System Information1. Go to Administration > System Information in Exper

Página 253

Administration Menu & Forms 296Figure 11-2: Expert > Administration > NotificationsYou can use this form to set up alarm notifications abou

Página 254

BLACK BOX® CS Installation, Administration, and User’s Guide 297 Clicking the Add button or selecting a previously specified event and clicking the E

Página 255

Administration Menu & Forms 298Figure 11-3: Expert > Administration > Notifications > Email > Add/Edit Dialog boxThe following table

Página 256 - Security Profiles

BLACK BOX® CS Installation, Administration, and User’s Guide 299 T To Configure a Trigger for Email Notification for Serial Ports1. Go to Administrat

Página 257 - Pre-defined Security Profiles

BLACK BOX® CS Installation, Administration, and User’s Guide 3Related Documents10: Ports Menu & FormsProvides an overview of each form associated

Página 258

Administration Menu & Forms 300Pager Notifications EntryWhen you go to Administration > Notifications, select “Pager” from the pull-down menu,

Página 259

BLACK BOX® CS Installation, Administration, and User’s Guide 301 The following table describes the available fields in the pager notification entry d

Página 260

Administration Menu & Forms 3026. Enter or change the Short Message Services (SMS) username, the SMS server’s IP address or name, and the SMS por

Página 261

BLACK BOX® CS Installation, Administration, and User’s Guide 303 Figure 11-5: Expert > Administration > Notifications > SNMP Trap > Add/E

Página 262

Administration Menu & Forms 304TTo Configure a Trigger for SNMP Trap Notification for Serial Ports1. Go to Administration > Notifications in E

Página 263

BLACK BOX® CS Installation, Administration, and User’s Guide 305 3. Select Email, Pager, or SNMP Trap from the pull-down menu.4. Click the Add button

Página 264

Administration Menu & Forms 306Figure 11-7: Expert > Administration > Time/Date > NTP EnableSetting Time and Date with NTP NTP (Network

Página 265

BLACK BOX® CS Installation, Administration, and User’s Guide 307 4. Type the IP address of the NTP server in the “NTP Server” field. 5. Click “OK.”6.

Página 266 - Security Certificates

Administration Menu & Forms 308The following table describes the boot configuration form fields.Table 11-7: Expert > Boot Configuration Form F

Página 267 - Ports Menu & Forms

BLACK BOX® CS Installation, Administration, and User’s Guide 309 T To Configure CS Boot 1. Go to Administration > Boot Configuration in Expert mod

Página 268

Before You Begin4The following table describes other terms and conventions.BLACK BOX® firmware UpgradesBLACK BOX® offers periodic firmware upgrades fo

Página 269 - Physical Ports

Administration Menu & Forms 3108. Click “apply changes.” Backup ConfigurationSelecting Administration > Backup Config in Expert mode brings up

Página 270

BLACK BOX® CS Installation, Administration, and User’s Guide 311 The following table describes the available fields and buttons in the “Backup Config

Página 271

Administration Menu & Forms 312Figure 11-10: Expert > Administration > Backup Config > Storage DeviceThe following table describes the a

Página 272 - Connection Profiles

BLACK BOX® CS Installation, Administration, and User’s Guide 313 directory path. For example, /upload/zvmppccs.0720_qa.cs-k26.5. Enter the username a

Página 273

Administration Menu & Forms 314Figure 11-11: Expert > Administration > Upgrade FirmwareYou can use this form to configure an automated upgr

Página 274

BLACK BOX® CS Installation, Administration, and User’s Guide 315 T To Upgrade the CS’s firmwareThis procedure is for upgrading the latest release of

Página 275 - Bidirectional Telnet Protocol

Administration Menu & Forms 316RebootSelecting Administration > Reboot in Expert mode brings up the form shown in the following figure.Figure

Página 276 - Console Connection

BLACK BOX® CS Installation, Administration, and User’s Guide 317 Online HelpSelecting Administration > Online Help in Expert mode brings up the fo

Página 277

Administration Menu & Forms 3183. In the “Online Help Path” field configure the path to the location of the documenation on your local server.Not

Página 278 - Bidirectional Telnet

Appendix ATechnical SpecificationsThe following table lists the Advanced Console Server hardware specificationsCPU MPC855T (PowerPC Dual-CPU)Memory 1

Página 279

IntroductionThis chapter introduces the Advanced Console Server family of advanced console servers, provides an overview of its features, and briefly

Página 280 - Terminal Server

Technical Specifications320Certification FCC Part 15, AEN55022, A (CE)EN55024UL 1950Solaris Ready™

Página 281

Appendix BSafety, Regulatory, and ComplianceInformationThe following Safety Information for Advanced Console Server are described in this appendix. Sa

Página 282 - External Modem

Safety, Regulatory, and Compliance Information322TemperatureThe manufacturer's maximum recommended ambient temperature for the Advanced Console S

Página 283

BLACK BOX® CS Installation, Administration, and User’s Guide 323 Safety Precautions for Operating the Advanced Console

Página 284

Safety, Regulatory, and Compliance Information3240.75 mm2 or above cable to connect the DC configured unit to the Centralized D.C. Power Systems. Inst

Página 285

BLACK BOX® CS Installation, Administration, and User’s Guide 325 FCC Warning StatementCaution: Bei Einsetzen einer fal

Página 286

Safety, Regulatory, and Compliance Information326Aviso de Precaución S-Mark ArgentinaPor favor de leer todos los avisos de precaución como medida prev

Página 287

BLACK BOX® CS Installation, Administration, and User’s Guide 327 Trabajar dentro del Advanced Console Server1999. Para

Página 288

Safety, Regulatory, and Compliance Information328

Página 289

Appendix CSupported PCMCIA CardsBLACK BOX® CS supports the PCMCIA cards listed in the table below. Note that some PCMCIA cards have been discontinued

Página 290

Introduction 6OverviewThe Advanced Console Server is a 1U device that serves as a single access point for using and administering servers and other

Página 291

Supported PCMCIA Cards33010/100BT Ethernet& V.90 (56k) Modem ComboXircom XEM5600 10/100BT Ethernet and 56k V.90 modem combination (Discontinued)80

Página 292

BLACK BOX® CS Installation, Administration, and User’s Guide 3311WARNING: Consult your local GSM service provider for coverage areas and support of th

Página 293

Supported PCMCIA Cards332

Página 294 - Data Buffering

GlossaryAuthentication The process by which a user’s identity is checked within the network to ensure that the user has access to the requested resour

Página 295

Glossary334BogoMips BogoMips (from "bogus" and MIPS). Unscientific measurement of CPU speed made by the Linux kernel when it boots to calibr

Página 296

BLACK BOX® CS Installation, Administration, and User’s Guide 335assigning IP addresses without using the standard IP address classes like Class A, Cla

Página 297

Glossary336Console Terminal used to configure network devices at boot (start-up) time. Also used to refer to the keyboard, video and mouse user interf

Página 298 - Multi User

BLACK BOX® CS Installation, Administration, and User’s Guide 337than one machine. Usually, all of the machines on a given Network will have the same t

Página 299

Glossary338Flow Control A method of controlling the amount of data that two devices exchange. In data communications, flow control prevents one modem

Página 300 - More Serial Ports

BLACK BOX® CS Installation, Administration, and User’s Guide 339Each address has a network number, an optional sub network number and a host number. T

Página 301 - Power Management

BLACK BOX® CS Installation, Administration, and User’s Guide 7 Product Models and ConfigurationsThe following figure illustrates the BLACK BOX® fami

Página 302

Glossary340After a client and server has used Kerberos to prove their identity, they can also encrypt all of their communications to assure privacy an

Página 303

BLACK BOX® CS Installation, Administration, and User’s Guide 341Trial and error is the only sure way of finding the optimal MTU, but there are some gu

Página 304

Glossary342255.255.255.0), however, its value is needed to be understood as a 32-bit number with certain number of ones on the left end and zeros as t

Página 305

BLACK BOX® CS Installation, Administration, and User’s Guide 343initial 1 in this OID is directly below root. This is called an absolute OID. However,

Página 306

Glossary344developed a standard for small, credit card-sized devices, called PC Cards. Originally designed for adding memory to portable computers, th

Página 307

BLACK BOX® CS Installation, Administration, and User’s Guide 345service. RADIUS allows a company to maintain user profiles in a central database that

Página 308

Glossary346sending messages, called protocol data units (PDUs), to different parts of a network. SNMP-compliant devices, called agents, store data abo

Página 309 - Connected to a Console

BLACK BOX® CS Installation, Administration, and User’s Guide 347characteristics, usually those that differ from implementation-dependent defaults. Oth

Página 310

Glossary348terminal servers are sometimes used as console access servers. TTY 1. In Unix, refers to any terminal; sometimes used to refer to the parti

Página 311 - Virtual Ports

BLACK BOX® CS Installation, Administration, and User’s Guide 349The timer can also be used for other purposes, for example, to actuate the refresh (or

Página 312

Introduction 8Connectors on the BLACK BOX® CSThe following figure depicts the connectors on the back of a LS1008A. Figure 1-3: LS1008A ConnectorsThe

Página 313

Glossary350

Página 314

IndexAaccess 259allow SSH root 79, 228root 345SSH root 118access requirements, port 54access server(CAS) profile, console 243(CAS), console 242, 335ac

Página 315

Index352raccess 220user 220authorized users/groups 260authtype 215, 216Bbackup configuration 310banner, console 154banner, login 279basic installation

Página 316

BLACK BOX® CS Installation, Administration, and User’s Guide 353boot 307firewall 186configuringaccess to connected devices 23authentication for CS log

Página 317 - Ports Status

Index354File Size 99Local files 99Mode 98NFS File Path 99off-line 343Remote server 99time stamp 99, 266data size 89data buffering events 297default IP

Página 318 - Ports Statistics

BLACK BOX® CS Installation, Administration, and User’s Guide 355FTP site 315Ggateway IP 154Group Authorization on LDAP 222Group Authorization on RADIU

Página 319

Index356Kkeep-alive interval, TCP 278, 347Kerberos 11, 224, 262, 339Kerberos/local 11, 217, 262Kerberosdownlocal 11, 217, 262key, IPMI 273key, power m

Página 320

BLACK BOX® CS Installation, Administration, and User’s Guide 357Nnavigation shortcuts 4NEBS 341NEBS certification 324network mask 154, 341network menu

Página 321 - Chapter 11

Index358PCPU processing time 213physical ports 239planning access to connected devices 22plug-in, Java 33PM IPDUs, connecting AltherPath 47port 344des

Página 322 - System Information

BLACK BOX® CS Installation, Administration, and User’s Guide 359RAS 242RAS, modem 242raw socket 245raw, console 243reboot 316reboot the CS 316record t

Página 323

BLACK BOX® CS Installation, Administration, and User’s Guide 9 Web ManagerNote: If there are cron jobs running through automated scripts, a “root” o

Página 324

Index360SNMP traps 346SNMP, simple network management protocol 181SNMPv1 303SNMPv2 303SSH (secure shell) 346SSH root access 118SSH root access, allow

Página 325 - Notifications

BLACK BOX® CS Installation, Administration, and User’s Guide 361trap notification, SNMP 304trap number 303traps, SNMP 346trigger, alarm 298TS profile

Página 326

Index362XX.509 Cerfiticate on SSH 236

Página 327 - Email Notifications Entry

ContentsivSyslog Servers ... 23Prerequisites for Logging to Syslog Serve

Página 328

Introduction 10• Make an inquiry to the DHCP server on the subnet that the CS resides, using the MAC address (The MAC address is labeled at the bott

Página 329

BLACK BOX® CS Installation, Administration, and User’s Guide 11 AuthenticationAuthenticationCS supports a number of authentication methods that can

Página 330 - Pager Notifications Entry

Introduction 12Local/TACACS+Authentication is performed locally first, switching to TACACS+ if unsuccessful.Local/NISAuthentication is performed loc

Página 331

BLACK BOX® CS Installation, Administration, and User’s Guide 13 VPNVPNThe CS administrator can set up VPN connections to establish an encrypted comm

Página 332 - SNMP Trap Notifications Entry

Introduction 14ChainA chain is a named profile that includes one or more rules that define the following:• A set of characteristics to look for in

Página 333

BLACK BOX® CS Installation, Administration, and User’s Guide 15 Packet Filtering on CSAdd Rule and Edit Rule OptionsWhen you add or edit a rule you

Página 334

Introduction 16packets arriving from any other source IP address than the one specified are dropped.Numeric Protocol OptionsIf you select Numeric as

Página 335 - Time/Date

BLACK BOX® CS Installation, Administration, and User’s Guide 17 Packet Filtering on CSUDP Protocol OptionsWhen you select UDP as a protocol when spe

Página 336

Introduction 18• precedence-cutoff• source-quench•redirect• network-redirect• host-redirect• TOS-network-redirect• TOS-host-redirect• echo-request•

Página 337 - Boot Configuration

BLACK BOX® CS Installation, Administration, and User’s Guide 19 Packet Filtering on CSIf the “LOG” and “REJECT” targets are selected, additional opt

Página 338

BLACK BOX® CS Installation, Administration, and User’s Guide vChapter 3: Web Manager for Regular Users...51Using the Web Manager ...

Página 339 - To Configure CS Boot

Introduction 20Firewall Configuration ProceduresThe following table has links to the procedures for defining packet filtering using the Web Manager.

Página 340 - Backup Configuration

BLACK BOX® CS Installation, Administration, and User’s Guide 21 Notifications, Alarms, and Data BufferingNotifications, Alarms, and Data BufferingTh

Página 341

Introduction 22An Example of Using Facility NumbersThe syslog system administrator sets up a server called “syslogger” to handle log messages from t

Página 342

BLACK BOX® CS Installation, Administration, and User’s Guide 23 CS and Power ManagementConfiguring Access to Connected DevicesDuring hardware instal

Página 343 - Upgrade Firmware

Introduction 24commands. Authorized users can also perform IPMI power management of serially-connected devices. The CS uses IPMI V1.5. • Remote powe

Página 344

BLACK BOX® CS Installation, Administration, and User’s Guide 25 CS and Power ManagementThe following table list the tasks for power management and w

Página 345 - To Upgrade the CS’s firmware

Introduction 26Options for Managing Power The sections listed below describe the different ways that the authorized users can perform power manageme

Página 346 - To Reboot the CS

Chapter 2Installation and ConfigurationThis chapter covers the topics listed in the following table.The following figure illustrates an example of an

Página 347 - Online Help

Installation and Configuration 28Figure 2-1: CS Setup ExampleShipping Box ContentsThe shipping box contains the CS along with the items shown in Tab

Página 348

BLACK BOX® CS Installation, Administration, and User’s Guide 29 Shipping Box Contents3.Power cable. To connect the CS to a power source. 4.RJ45 to

Página 349 - Technical Specifications

ContentsviStep 3: Port Profile ... 90Step 4: Access ...

Página 350

Installation and Configuration 309.RJ45 to DB25M straight-thru cableUse for modems and other DCE devices.10.DB25F Loopback Use to test and diagnose

Página 351 - Information

BLACK BOX® CS Installation, Administration, and User’s Guide 31 Shipping Box ContentsTable 2-2: Shipping Box Contents for LS1001AR Item Description

Página 352 - Console Server

Installation and Configuration 32Important Pre-installation RequirementsBefore installing and configuring CS, ensure that you have the following:• R

Página 353

BLACK BOX® CS Installation, Administration, and User’s Guide 33 Important Pre-installation RequirementsJava Plug-In Requirement for Serial Port Acce

Página 354 - Replacing the Battery

Installation and Configuration 34If needed, download the JRE from http://java.com. The web site automatically checks your configuration and installs

Página 355 - Canadian DOC Notice

BLACK BOX® CS Installation, Administration, and User’s Guide 35 Basic Installation ProceduresMounting the CSYou can mount the CS on a wall, rack, or

Página 356

Installation and Configuration 36TTo Make an Ethernet Connection1. Connect the RJ-45 end of the cable to the port labeled “Console” on the CS.2. Con

Página 357

BLACK BOX® CS Installation, Administration, and User’s Guide 37 Basic Installation ProceduresMaking a Direct Connection to Configure the Network Par

Página 358

Installation and Configuration 38Note: If your CS model is equipped with dual power supplies, make sure you turn both power switches on. After syst

Página 359 - Supported PCMCIA Cards

BLACK BOX® CS Installation, Administration, and User’s Guide 39 Basic Installation ProceduresNote: It is strongly recommended to change the default

Página 360

BLACK BOX® CS Installation, Administration, and User’s Guide viiConfiguring an Ethernet PCMCIA Card ... 171Configuring

Página 361

Installation and Configuration 40Figure 2-2: Security Advisory Console MessageT To Use the wiz Command to Configure Network Parameters1. Launch the

Página 362

BLACK BOX® CS Installation, Administration, and User’s Guide 41 Basic Installation ProceduresAs shown in the sample screen below, the system brings

Página 363 - Glossary

Installation and Configuration 425. To change the default static IP address, see your network administrator to obtain a valid IP address.6. Enter th

Página 364

BLACK BOX® CS Installation, Administration, and User’s Guide 43 Basic Installation ProceduresNote: To use the Web Manager, ask your system administr

Página 365

Installation and Configuration 44• Access the serial ports and the connected devices. Adding Users and Configuring Ports Using the Web ManagerEnabli

Página 366

BLACK BOX® CS Installation, Administration, and User’s Guide 45 Other Methods of Accessing the Web ManagerOther Methods of Accessing the Web Manager

Página 367

Installation and Configuration 462. Bring up a browser on the computer whose address you changed, enter the CS’s default IP address, http://192.168.

Página 368

BLACK BOX® CS Installation, Administration, and User’s Guide 47 Connecting AlterPath PM IPDUsFigure 2-4: PCMCIA Eject Button in Web Manager2. Physic

Página 369

Installation and Configuration 48Figure 2-5: AlterPath PMs Connected to the CSThe following table lists the related tasks on connecting IPDU units a

Página 370

Chapter 3Web Manager for Regular UsersThis chapter describes the requirements and the procedures for “Regular Users” to use the Web Manager. Regular

Página 371

ContentsviiiGeneral ... 243Connection Profiles ...

Página 372

Web Manager for Regular Users 50The CS administrator can use the Web Manager to configure users and ports. An authorized user can access connected d

Página 373

BLACK BOX® CS Installation, Administration, and User’s Guide 51 Features of Regular User FormsFeatures of Regular User FormsThe following figure sho

Página 374

Web Manager for Regular Users 52ConnectWhen you select the “Connect” option, the following form appears.Figure 3-3: Regular User > Connect FormYo

Página 375

BLACK BOX® CS Installation, Administration, and User’s Guide 53 ConnectConnect to CSWhen you click the “Connect to CS” radio button on the “Connect”

Página 376

Web Manager for Regular Users 54Connect to Serial PortsThe list of serial ports includes the port names or administrator-defined aliases only for po

Página 377

BLACK BOX® CS Installation, Administration, and User’s Guide 55 Connectdepending on your requirements. The following table shows the protocols the

Página 378

Web Manager for Regular Users 56TTo Use SSH to Connect to a Device Through a Serial PortFor this procedure, you need the username configured to acce

Página 379

BLACK BOX® CS Installation, Administration, and User’s Guide 57 IPDU Power Mgmt.Outlets ManagerWhen you go to IPDU Power Mgmt.>Outlets Manager ta

Página 380

Web Manager for Regular Users 58The form shows separate entries for each serial port configured for power management, a name for the configured seri

Página 381

BLACK BOX® CS Installation, Administration, and User’s Guide 59 IPDU Power Mgmt.View IPDUs InfoWhen you go to IPDU Power Mgmt.>View IPDUs Info, t

Página 382

BLACK BOX® CS Installation, Administration, and User’s Guide ixformation ...323Safety Gui

Página 383

Web Manager for Regular Users 60IPDU Multi-Outlet CtrlSelecting IPDU Multi-Outlet Control form allows you to view and manage the power on a group of

Página 384

BLACK BOX® CS Installation, Administration, and User’s Guide 61 IPDU Multi-Outlet Ctrlpower supply device is connected to are on the same PM or not,

Página 385

Web Manager for Regular Users 62Figure 3-10: Regular User > IPDU Multi-Outlet (with permissions)Notice in the above figure that the first line of

Página 386

BLACK BOX® CS Installation, Administration, and User’s Guide 63 Securityoutlet in the group turns on only after the power up interval specified for

Página 387

Web Manager for Regular Users 64

Página 388

Chapter 4Web Manager for AdministratorsOverviewThis chapter is for system administrators who use the Web Manager to configure the CS and its users. F

Página 389

Web Manager for Administrators 66BLACK BOX® Web ManagerCS administrators perform most tasks through the BLACK BOX® Web Manager either locally or fro

Página 390

BLACK BOX® CS Installation, Administration, and User’s Guide 67 Common Tasks for CS AdministratorsCommon Tasks for CS AdministratorsThe following ta

Página 391

Web Manager for Administrators 68Common Features of Administrator FormsThe common features of all Web Manager forms for CS administrators are descri

Página 392 - X.509 Cerfiticate on SSH 236

BLACK BOX® CS Installation, Administration, and User’s Guide 69 Common Features of Administrator FormsThe various Web Manager actions for trying, sa

Comentários a estes Manuais

Sem comentários