5-30 Compact T1 - Release 6.1
CLI Commands
alarms
alarms
Use the alarms command to display the active alarms. Each alarm is related to a particular
address and has a severity category (major, minor, critical, alert). The report can be filtered by
port address and/or severity.
Syntax: alarms [slot|slot:port|slot:port:channel] [category]
[severity]
Example: alarms
Time Date Severity Description
07:35:45 01/04/2002 Major Test Major Alarm
07:35:21 01/04/2002 Minor Test Minor Alarm
07:34:57 01/04/2002 Critical Test Critical Alarm
00:00:20 01/01/2002 Major 5:1-RTR Ethernet Link Down
00:00:05 01/01/2002 Major A:2-DS1 Loss Of Signal
Total=10
[slot|slot:port|slot:port:channel]
[category]
[severity]
slot A for the controller card, or 1 - 6 for service cards.
port Port number.
channel Channel number
bri All BRI facility alarms
ds1 All DS1 facility alarms
env Environmental Alarms
equipment Equipment alarms not related to a DS1 interface
fxo All FX0 facility alarms
fxs All FXS facility alarms
rtr All Router facility alarms
v35 All V.35 facility alarms
alert Alert alarms (threshold crossing)
critical Critical alarms
info Information alarms
major Major alarms (service effecting)
minor Minor alarms (non-service affecting)