5-78 Compact T1 - Release 6.1
CLI Commands
set
on Enable detection
off Disable detection
payload Apply a payload loopback to the DS1 interface. If the payload
command is not used, the default for payload loopback is loopdown.
loopdown Disable the payload loopback
loopup Enable the payload loopback
threshold
Set defect thresholds for a DS1. Defaults for all are 0.
day Set threshold for a daily interval
bes Bursty errored seconds range: 0 - 86400
css Controlled slip seconds range: 0 - 86400
dm Degraded minutes range: 0 - 1440
es Errored seconds range: 0 - 86400
lcv Line code violations range: 0 - 133401600
les Line errored seconds range: 0 - 86400
pcv Path code violations range: 0 - 133401600
sefs Severely errored frame seconds range: 0 - 86400
ses Severely errored seconds range: 0 - 86400
uas
Unavailable seconds range: 0 - 86400
min15 Set threshold for a 15 minute interval
bes Bursty errored seconds range: 0 - 900
css Controlled slip seconds range: 0 - 900
dm Degraded minutes range: 0 - 15
es Errored seconds range: 0 - 900
lcv Line code violations range: 0 - 1389600
les Line errored seconds range: 0 - 900
pcv Path code violations range: 0 - 1389600
sefs Severely errored frame seconds range: 0 - 900
ses Severely errored seconds range: 0 - 900
uas
Unavailable seconds range: 0 - 900
Vista de página 161