Euro MotoElectrics, 25958 Genesee Trail Road PMB 321 Golden, Colorado USA 80401 EDL-IGN Page 18 of 43
www.EuroMotoElectrics.com info@euromotoelectrics.com Tel: 1-303-526-0901
EnDuraSpark Electronic Ignition
Installation & Troubleshooting v5.1
1. The green/yellow stripe wire that was connected to the original ignition control unit
connects to one side of the Relay coil terminal.
2. Connect the Red wire from the EnduraSpark Black Box to the same terminal
3. Connect the other Relay Coil terminal to a good frame ground terminal
4. Connect the original green switched wire of the ignition coil to one side of the switch
terminals of the relay
5. Connect the other switch terminal of the relay and connect to the left ignition coil.
6. Continue with connecting the Black trigger wire from the Black Box to the right coil, and
the Brown wire from Black Box to ground.
7. Connect the thin black tachometer wire to the same terminal of the trigger wire. Verify all
connections.
With the key switch on and the kill switch in the on or run position, there will now be power to
the EnduraSpark Black Box and the relay will be energized.
By switching the kill switch to off, the power is cut to the relay and Black Box, as well as killing
power to the ignition coils.
Red lead to black box
Original ignition
control wiring
Ground connection
Switched power
Left coil
Vista de página 17