Testing the Wires and Caps
The spark plug caps, wires, and secondary coil resistance can be all checked together by doing a
“cap” to “cap” resistance test. For single-plugged engines, leave everything connected and test the
resistance between the inside of one cap to the other. This tests both coils, both caps, and both
wires. The value should be 12K 27K ohms.
For dual-plugged engines, check between the two caps on a single coil. The value should be 16K
24K. Check both coils in this fashion. If any measurement is out spec, disconnect the individual
components and check singly.