Section 2.2.2 Connecting to an Advant Controller 460
3BUR 001 085R0001 REV A 2-13
An Advant Controller 460 CPU (PM510) can support up to four MVI submodules for a total of
eight serial ports, Figure 2-10.
MVI to SHIM (RS-232) for an Advant Controller 460
For RS-232 communication, an MVI serial port is connected to a single SHIM in a point-to
point fashion using a single RS-232 cable as shown in Figure 2-11.
Up to 8 SHIMs can be connected to each CPU of the AC 460.
The MVI settings, cabling, and SHIM settings are the same as for the AC 410.
Figure 2-10. Advant Controller 460 Connection to MVI
Figure 2-11. RS-232 Communications to a Smart Device in an AC460
AC460 Controller Subrack
CI532V02
Serial Port 4/5
Serial Port 4/6
Serial Port 4/7
Serial Port 4/8
Serial Port 3/1
Serial Port 3/2
Serial Port 3/3
Serial Port 3/4
PM
510
CPU 1/A
CPU 1/B
510
PM
Port 4/7
SHIM
(RS-232)
MVI
CI532V02
XMTR
XMTR
1-8